CONTROL4
/
PRO
SERIES
I
ntegration
Guide
Control4 is a smart home automation and control system,
which integrates with ProSeries security systems to provide
enhanced home security and automation capabilities.
This integration
allows users to control their First Alert alarm
systems through the Control4 platform, receiving alerts and managing security features from a single interface.
Control4 achieves this by utilizing certified
drivers
and the
Simple Device Discovery
Protocol (SDDP),
which simplifies the
process of configuring devices by automatically discovering and adding compatible devices. Integrating with ProSeries
security control panels, allows for remote monitoring and control of alarms, cameras, and other secu
rity devices.
When the ProSeries Control Panel is discovered, the IP address and other key pairing information is passed on to
Control4
, which then
automatically
downloads the specific integration driver from the internet
.
ProSeries and Control4
must be paired through a pairing process to allow specific security
-
related awareness and functions to be performed from
one central location
.
This pairing process
must be
enabled from both the Control4 side and the ProSeries side.
AlarmNet
360 (AN360) is a cloud
-
based management
platform which provides the ProSeries Control Panel with a Control4 feature
flag,
and
when enabled allows ProSeries to communicate with and to be paired with Control4.
When
successfully
paired,
all network communication between Control4 and ProSeries is
processed
through the same local route
r.
PREREQUISITES
Prerequisites for
Control4
and
ProSeries
integration
:
?
Requires Control4 OS 4.
1
.0 or later and Composer Pro software.
?
Requires ProSeries software version 03.2476.18
3
or later.
?
P
roSeries Control P
anel must have all partitions and zones configured before adding
the
driver to the Control4
project.
?
AN360 must be configured to enable
the
Control4
feature
, which is part of the Smart Home
package
(
Packages > Smart Home > Add
-
Ons > Control4
)
.
?
Control4 and ProSeries must
have network communication over
the same local router
.
N
ote
:
Changing the IP address of the
Control P
anel
will
cause loss of control.
It is
recommend
ed to
set up a
Dynamic
Host Configuration Protocol (
DHCP
)
reservation for the
Control P
anel in the local router
.
?
AUTOMATIC SETUP USING CONTROL4 SDDP
To automatically set up and add the
integration
drive to the Control4 system using SDDP, perform the following:
1.
From
Composer Pro
,
initiate the discovery of
the ProSeries Control Panel
:
?
Select
System Design
>
Items
>
Discovered
.
2.
Double
-
click on the discovered ProSeries
integration
driver
.
?
The
applicable
driver
is
downloaded from the internet
?
The IP address and other key pairing information is sent to
Composer Pro.
?
The ProSeries integration driver is added to the Control4 Controller
and connected to the IP address of the
ProSeries Control Panel.
3.
From Composer Pro,
pair the driver to the ProSeries Control Panel
:
?
Select
Actions
>
Start Pairing
.
?
The
pairing process will timeout after 120 seconds if unsuccessful.
Control4
is now ready to be paired with ProSeries
(transmits a pairing request)
.
PAIR
CONTROL4 AND PROSERIES
To pair the ProSeries Control Panel
to
the Control4
C
ontroller, perform the
following:
1.
From the
m
enu, select the
Tools
option.
2.
Enter the installer PIN to display the
Tools
menu options.
3.
S
croll down and s
elect the
Control4 Controller
option.
Note:
The
Control4 Controller
option is only displayed when Control4
service has been enabled through
the
AN360 Programming Tool.
4.
Selec
t the
Pair Controller to Control4 Controller
option
to start the pairing process.
?
ProSeries is put in a pairing mode (receives the pairing
request).
?
If the pairing is successful, the
Control4 Controller information
is automatically populated.
If
the pairing is unsuccessful, the
Control4 Controller information
fields remain unpopulated.
?
The p
airing
process
will timeout after 120 seconds if
unsuccessful.
?
A ProSeries Control Panel
can only be paired
to
one Control4
Controller; however, m
ultiple ProSeries
Control P
anels can be
paired
to
the same
Control4
C
ontroller.
If
you want to pair a ProSeries Control Panel
to
a different Control4 Controller, you must first unpair that
connection and then you can pair with
that
different Control4 Controller.
VERIFY CONTROL4 AND PROSERIES INTEGRATION
To verify a successful integration, perform the following:
1.
From the
Control4
Composer Pro, select
Properties
to display the
Partitions
.
T
he partitions from the Control Panel
will be displayed in this field
as they are imported
.
?
When the
se partitions
start communicating with Co
ntrol4
, the
Partition State
will update
from Unknown to the
current state
(may take a minute
to load
).
o
Verify all Partitions are displayed
in the left pane (with their
status
)
.
?
From the
Advanced Properties
field, select
Get C4 Contacts
to update
/
display the
individual
zones
and
sensors
for
th
e
Control Panel.
o
Verify all
Zones
within each partition
are displayed
in the left pane
(with their current status)
.
If a new zone
has been added or removed
,
it will
display wh
ich
zone was added or deleted.
2.
From the
Control4
Touch
s
creen
(or mobile app)
, select the
Security
and verify all pa
rtition
s for the new ProSeries
Control Panel are displayed
.
If the
partitions are
not displayed,
verify the device visibility settings from
Composer Pro
.
?
From the
left pane
, select
ProSeries
and
from
Properties
,
select the
Navigator
tab
.
?
Select
the
Security
menu
option
to display the
Device Visibility
screen indicating which partitions are
Visible
and
Hidden
.
If
necessary,
select
M
odify
and
move
a
partition from
Hidden
to
Visible
.
?
Select
File
>
Refresh Navigators
to
refresh
and
display
a
ll
visible
partitions.
Hidden partitions will not be
displayed on the touchscreen
(
or
mobile app
)
.
3.
From the Control4 Touchscreen (or mobile app),
test
each
partition/zone.
?
S
elect
Home
to display overall status (armed/disarmed, secured, etc.).
?
Select
Zones
to display the status of
each
sensor and
device
within the partition
.
o
Trigger each sensor (open
/c
lose
, motion detect, etc.
) and v
erify the displayed status matches the actual zone
condition.